Table 1 MRI Parameters

From: Improving MR sequence of 18F-FDG PET/MR for diagnosing and staging gastric Cancer: a comparison study to 18F-FDG PET/CT

 T2W-HASTET2W-BLADEDWIT1-VIBE-dixon
TR (ms)2680300086004.04
TE (ms)83119721.24/2.47
Slice thickness (mm)3253
Slice gap (mm)0.60.410.6
FOV (mm)236 × 320380 × 380270 × 360328 × 420
Matrix378 × 512320 × 32082 × 110188 × 320
Flip angle(°)1408012
Echo chain length3783882
Bandwidth61050519761040
Fat suppression+
NEX131
Voxel size (mm3)0.6 × 0.6 × 3.01.2 × 1.2 × 2.03.3 × 3.3 × 5.01.8 × 1.3 × 3.3
BLADE coverage100%